MODEL 760
VACTRON SERIES
OPERATING INSTRUCTIONS
1-800-257-3872 TOLL FREE
1-978-264-0292 FAX
www.setra.com WEB
Certified
ISO
9001
Przeglądanie stron 0
1 2 3 4 5 6 ... 17 18

Podsumowanie treści

Strona 1 - OPERATING INSTRUCTIONS

MODEL 760VACTRON SERIESOPERATING INSTRUCTIONS1-800-257-3872 TOLL FREE1-978-264-0292 [email protected] EMAILwww.setra.com WEB✓CertifiedISO9001

Strona 2

Figure 5: Pin out of D-sub Connector (Code D2)Pin Location Function2 Signal Output5 Power Supply Common6 Power Supply, -15 VDC7 Power Supply, + 15 VDC

Strona 3 - Contents

4.0 OPERATIONFor most accurate pressure measurement, allow the Model 760 to warmup for at least 15 minutes. After installation, periodically check the

Strona 4 - 1.0 Introduction

5.0 Calibration & Adjustment5. 1 Checking & Zero AdjustmentAfter installation on a system, the Model 760 may require initial zero adjust-ment

Strona 5 - 2.0 Mechanical Installation

6.0 Maintenance & TroubleshootingThere are no general maintenance requirements for the Model 760 other thanperiodic zero adjustment. If the unit f

Strona 6

7.0 SpecificationsPerformance Data:Accuracy (RSS)1 :< ± 0.25% of ReadingOptional < ± 0.15% of ReadingResolution: 0.01% FSThermal effectsCompensa

Strona 7

8.0 Reordering DataExample: To order a 10 Torr FS unit with ISO NW16 fitting, 0-10 VDC output, Dsub 15 electrical connector and an accuracy of ±0.25%

Strona 8 - 3.0 Electrical Installation

diagrams. Allow approximately 3 weeks after receipt at Setra for the repairand return of the unit. Non-warranty repairs will not be made withoutcust

Strona 9

11.0 RETURN OF SETRA SYSTEMS PRODUCT-DECLARATION(Form 760ERN)EXPECTED RETURN NUMBER _____________________________________________You must:• Know abou

Strona 10 - Pin Location Function

MODEL 760VACTRON SERIESOPERATING INSTRUCTIONS1-800-257-3872 TOLL FREE1-978-264-0292 [email protected] EMAILwww.setra.com WEB✓CertifiedISO9001159 Swan

Strona 11 - 4.0 OPERATION

Setra offers a complete line of productsfor the semiconductor industry.Model 212FT True Flow-ThroughPressure TransducerModel 216 and 225 Low Cavity Vo

Strona 12

Contents1.0 Introduction... 12.0 Mechanical Installation..

Strona 13

1.0 IntroductionSetra's Vactron Model 760 capacitance manometer is a temperaturecompensated, absolute pressure transducer designed for accurate a

Strona 14 - 7.0 Specifications

2.0 Mechanical InstallationRemove all packaging material and the protective flange cover and visuallycheck the Model 760. If the Model 760 appears dam

Strona 15 - 8.0 Reordering Data

Figure 1: Outline drawing of 15 pin D connector, 0.5" OD tube. Figure 2: Outline drawing of screw terminal connector(6 position), 0.5" OD tu

Strona 16

Figure 3: Outline drawing showing optional ISO NW vacuum fitting.Figure 4: Outline drawing showing optional VCR™ style face sealvacuum fitting.4

Strona 17 - (Form 760ERN)

3.0 Electrical InstallationThe pin out for the D-sub, 15 pin connector is shown in Figures 5, page 6.A schematic diagram of the recommended electrical

Strona 18

Figure 5: Pin out of D-sub Connector (Code D2)Pin Location Function2 Signal Output5 Power Supply Common6 Power Supply, -15 VDC7 Power Supply, + 15 VDC