Setra-system Model 231RS Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Setra-system Model 231RS. Setra System Model 231RS User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
Model 231RS Multi-Sense®
Wet-to-Wet Pressure Transducer
Remote Sensors
978-263-1400; 800-257-3872
www.setra.com; [email protected]om
CE
RoHS
231RS
Cable
Version
231RS
Armored
Cable
Version
231RS
Conduit
Version
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - Remote Sensors

1Model 231RS Multi-Sense®Wet-to-Wet Pressure TransducerRemote Sensors978-263-1400; 800-257-3872www.setra.com; [email protected] Cable Version

Strona 2

103.2 Electrical TerminationWiring: 3-Wire, 0 to 5, 0 to 10, 1-5 VDC and Remote ZeroModel 231RS when congured for voltage output is a 3-wire circuit

Strona 3 - Contents

113.3 Remote Sensors InstallationConduit Version (P/N: 231GRSX3MX)For conduit version remote sensors, use the following instructions:1. Install the re

Strona 4 - Model 231 Remote Sensors (RS)

123.3 Remote Sensors InstallationCable Version (P/N: 231GRSX4MXXXX)For cable version remote sensors, use the following instructions:1. Install the rem

Strona 5 - 2.0 MECHANICAL INSTALLATION

133.3 Remote Sensors InstallationArmored Cable Version (P/N: 231GRSXAJXXXX)For Armored Cable version remote sensors, use the following instructions:1.

Strona 6 - Model 231RS

144.0 CONFIGURATIONRange Selection Switch: The unit is set to the highest range when calibrated at the factory. To select the other ranges, slide the

Strona 7 - Outline Drawing

15SS231RS Rev D. 07/16/20145.0 RETURNING PRODUCTS FOR REPAIRPlease contact a Setra application engineer (800-257-3872, 978-263-1400) before returning

Strona 8

16159, Swanson Road, Boxborough, MA 01719978-263-1400; 800-257-3872/www.setra.com; [email protected] all CE technical questions, contact Setra System

Strona 10 - Figure 5

3Contents1.0 GENERAL INFORMATION 42.0 MECHANICAL INSTALLATION 52.1 Media Compatibility 52.2 Environment 52.3 Pressure Fittings 52.4 Mounting 62.5 Inst

Strona 11

4Installation GuideMulti-Sense® Model 231RS SeriesWet-to-Wet Dierential Pressure Transducers1.0 GENERAL INFORMATIONEvery Model 231RS has been calibra

Strona 12

52.0 MECHANICAL INSTALLATION2.1 Media CompatibilityModel 231RS transducers are designed to be used with any gas or liquid compatible with 17-4 PH stai

Strona 13 - Cable version)

62.4 MountingThe Model 231RS can be easily mounted using the two mounting screws located on the side of the unit.2.5 Installation ProceduresFor diere

Strona 14 - 4.0 CONFIGURATION

7Model 231RS (Conduit Version, P/N: 231GRSX3MXXX) - Outline DrawingFigure 21.9850.34.010.20.86421.952x0.9524.15.16131.11.5639.61.22030.991.24031.501/2

Strona 15 - SS231RS Rev D. 07/16/2014

8Model 231RS (Cable version, P/N: 231GRSX4MXXX) Model 231RS (Armored Cable Version, P/N: 231GRSXAJXXX)Outline DrawingFigure 32.050.81.22311.6642.26.0

Strona 16

93.0 ELECTRICAL INSTALLATIONTo access the electrical connections, turn the screws on the top of the case counter clockwise until the hinged cover can

Komentarze do niniejszej Instrukcji